0

UDC3200 Universal Digital Controller

UDC3200 Universal Digital Controller
UDC3200 Universal Digital Controller
Price And Quantity
  • Unit/Units
  • 1
  • Unit/Units
  • 1 INR
    Product Specifications
    • digital controller
    • Standard
    • 120 Vac or 240 Vac or 30 Vdc
    • 50/60 Hertz (HZ)
    • Standard
    • 1/4 DIN
    • 1 Year
    Product Description
    Features:
    • 2 Universal Analog Inputs
    • Fast scanning rate (166ms)
    • Up to 5 Analog Output Types
    • Math Functions
    • Ethernet and Modbus communication
    • Infrared PC & Pocket PC configuration
    • NEMA4X and IP66 front face protection
    • Multilanguage prompts
    • Jumper free configuration
    • Easily Field Upgradable
    • Bright, dual displays with multi-language prompts (in English, French, German,
    • Spanish, or Italian) make the operator interface easy to read, understand, and operate
    • Simple keystrokes let you set operating parameters that meet your process control needs

    Math Functions:
    • Algorithm-A pre-configured algorithm is available for easy
    • implementation.
    • This includes the capability of using a Ratio and Bias with any input.
    • You can select from the following menu: Feedforward Summer-Uses either input, followed by a Ratio/Bias calculation, summed directly with the computed PID output value to provide a resultant output to the final control element (standard feature).
    • Weighted Average Computes the weighted average of a PV or SP for the control algorithm from two inputs (standard feature)
    • Feedforward Multiplier-Uses any input, multiplied by the calculated PID output to provide a resultant output which is sent to the final control element (standard feature).
    • Summer/Subtractor-Will add or subtract inputs with the result used as the derived PV
    • Multiplier/Divider-Uses the analog inputs to calculate a derived PV
    • Available with or without Square Root
    • Input High/Low Select-Specifies the PV input as the higher or lower of the two inputs
    Digital Inputs:
    • Two isolated digital inputs are provided for remote dry contact closure to select one of the following actions: Manual control mode
    • Local setpoint 1
    • Local setpoint 2
    • Local setpoint 3
    • Direct controller action
    • Hold SP Ramp/Program
    • Select PID set 2
    • PV = Input 2
    • ReRun - SP Ramp/Program
    • Run - SP Ramp/Program
    • External program reset
    • Disable PID integral action
    • Manual mode, failsafe output
    • Disable keyboard
    • Output 1 = Fixed value
    • Start Timer
    • Auto/Manual Station
    • Initiate Tuning
    • Initiate PV Hot Start
    • Output 1 tracks Input 2
    • To Remote Setpoint
    • PID reset feedback via Input 2
    • Purge
    • Low Fire
    • To Latching Manual Mode.
    • Also, the digital inputs can allow one of the following selections to be combined with one of the above selections: Select PID set 2
    • Direct controller action
    • Local setpoint 2 or Local setpoint 1
    • Disable Accutune
    • To Run – SP Ramp/Program
    • The 2nd Current Output and the 2nd
    • Digital Input are mutually exclusive
    • Selection is made via a keyboard entry