UDC3200 Universal Digital Controller
Price And Quantity
- Unit/Units
- 1
- Unit/Units
- 1 INR
Product Specifications
- digital controller
- Standard
- 120 Vac or 240 Vac or 30 Vdc
- 50/60 Hertz (HZ)
- Standard
- 1/4 DIN
- 1 Year
Product Description
Features:
Math Functions:
- 2 Universal Analog Inputs
- Fast scanning rate (166ms)
- Up to 5 Analog Output Types
- Math Functions
- Ethernet and Modbus communication
- Infrared PC & Pocket PC configuration
- NEMA4X and IP66 front face protection
- Multilanguage prompts
- Jumper free configuration
- Easily Field Upgradable
- Bright, dual displays with multi-language prompts (in English, French, German,
- Spanish, or Italian) make the operator interface easy to read, understand, and operate
- Simple keystrokes let you set operating parameters that meet your process control needs
Math Functions:
- Algorithm-A pre-configured algorithm is available for easy
- implementation.
- This includes the capability of using a Ratio and Bias with any input.
- You can select from the following menu: Feedforward Summer-Uses either input, followed by a Ratio/Bias calculation, summed directly with the computed PID output value to provide a resultant output to the final control element (standard feature).
- Weighted Average Computes the weighted average of a PV or SP for the control algorithm from two inputs (standard feature)
- Feedforward Multiplier-Uses any input, multiplied by the calculated PID output to provide a resultant output which is sent to the final control element (standard feature).
- Summer/Subtractor-Will add or subtract inputs with the result used as the derived PV
- Multiplier/Divider-Uses the analog inputs to calculate a derived PV
- Available with or without Square Root
- Input High/Low Select-Specifies the PV input as the higher or lower of the two inputs
- Two isolated digital inputs are provided for remote dry contact closure to select one of the following actions: Manual control mode
- Local setpoint 1
- Local setpoint 2
- Local setpoint 3
- Direct controller action
- Hold SP Ramp/Program
- Select PID set 2
- PV = Input 2
- ReRun - SP Ramp/Program
- Run - SP Ramp/Program
- External program reset
- Disable PID integral action
- Manual mode, failsafe output
- Disable keyboard
- Output 1 = Fixed value
- Start Timer
- Auto/Manual Station
- Initiate Tuning
- Initiate PV Hot Start
- Output 1 tracks Input 2
- To Remote Setpoint
- PID reset feedback via Input 2
- Purge
- Low Fire
- To Latching Manual Mode.
- Also, the digital inputs can allow one of the following selections to be combined with one of the above selections: Select PID set 2
- Direct controller action
- Local setpoint 2 or Local setpoint 1
- Disable Accutune
- To Run – SP Ramp/Program
- The 2nd Current Output and the 2nd
- Digital Input are mutually exclusive
- Selection is made via a keyboard entry
Trade Information
- Telegraphic Transfer (T/T)
- Gujarat
Related Products
Contact Us
C-347, 3rd Floor, Sumel Business Park - 6, Nr. Dudheshwar Circle, Dudheshwar, Ahmedabad, Gujarat, 380004, India
Phone :+918045475874