Product Description
The UDC2500 monitors and controls temperatures and other variables in applications such as:
Product Details:
- Furnaces and ovens
- Environmental chambers
- Packaging machinery
- Plastic processing machines
Features:
- 1 Universal Input + 1 high level input
- Up to 5 Analog or Digital Output Types
- Ethernet and Modbus communication
- Infrared PC & Pocket PC configuration
- NEMA4X and IP66 front face protection
- Multilanguage prompts
- Jumper free configuration
- Easily Field Upgradable
- Downward compatibility with existing UDC2300 applications
- Limit model
Product Details:
- The standard features include Accutune IIITM and the popular single display, automatic mode model
- A Dual Display model with Automatic/Manual control modes is optional
- A Limit Control model is also available
- The UDC2500 provides a 1-4 DIN sized alternative for many applications
- Its features include: Universal AC power supply, optional RS422/485 Modbus RTU or Ethernet 10Base-T TCP/IP communication protocols, input/output isolation, Isolated Auxiliary Current output
- When these are combined with the Accutune IIITM tuning with fuzzy logic overshoot suppression, the result is price/performance leadership
- Configuration can be done with a PC through communication or with a Pocket PC, using the embedded infra red communication port
- No need to get access to the back of the controller to download or upload a brand new configuration
- For the many thousands of satisfied UDC2300 users, the UDC2500 is downward-compatible with most existing UDC2300 applications
Analog Inputs:
- The UDC2500 has two analog inputs with a typical accuracy of ±0.25% of full-scale input and a typical resolution of 16 bits
- Both analog inputs are sampled six times per second (every166 ms)
- The first input is a low-level type which accepts thermocouple, RTD, ma, mV and voltage types
- The second input is a high level type and can be used as a remote setpoint, for data acquisition or as a parameter to be alarmed on
- This input accepts ranges 0-5V, 1-5V, 0-2V, 0-20mA or 4-20mA
- Cold junction compensation is provided for thermocouple type inputs
- Upscale or downscale sensor break protection is keyboard configurable
- A configurable digital filter of 0 to 120 seconds provides input signal damping
- All input types are configurable via the keyboard, there are no internal jumpers or switches
- The two inputs are isolated from all other inputs and outputs, but not from each other
Thermocouple Health:
- In addition to the standard configurable upscale, downscale or failsafe output burnout selections
- The condition of the thermocouple can be monitored to determine if it is good, failing or in danger of imminent failure.
Communications:
- A communications link is provided between the UDC2500 and a host computer or PLC via the RS422/485
- Modbus® RTU or Ethernet TCP/IP communications option.
- An infrared communication link is also available allowing a non-intrusive configuration of the instrument.